Material
Specifications
Housings (Plug & Receptacle) - Thermoplastic
Seals - Silicone Elastomer
Secondary Locks - Thermoplastic
Contacts - Copper Alloy, Nickel Plated,
Gold Optional
General
Specifications
Dielectric
Withstanding Voltage (Test Voltage): Sea Level
1500 VAC (rms)
Current Rating (Maximum):
No 16 Pin or Socket 13 amps
Silicone
Insert:
Front and rear silicone inserts are devoid
of all organic matter.
ARC
Resistance: All dielectric materials withstand
a minimum of 130 seconds per ASTM D-495
Physical
Shock:
No unlocking, unmating or other unsatisfactory
result after 50g's in each of three mutually perpendicular
planes.
Dielectric
Strength: 1500 volts minimum.
Submersion:
Properly wired and mated connection will withstand
immersion under three feet of water without loss of
electronic qualities or leakage. |
Vibration:
Maintains continuity and exhibits no mechanical
or physical damage after vibration of 20 g's at 10-2000
Hz.
Temperature:
Operative at temperatures from -55°C to +125°C
(-67°F to +257°F ) at rated current.
Contact
Retention:
Contacts withstand a minimum load of 25 lbs. for size
16.
Thermal
Shock:
No cracking, chipping or leaking after 5
test cycles from -55°C to +125°C
Insulation
Resistance:
1000 megohms minimum at 25°C
Usable
Wire Size:
No. 16 contacts receive conductors
14-16 AWG or 16-18 AWG. Rear insert will seal on smooth
insulation from .088" to .145" O.D. Reduced
diameter seals optional.
Durability:
No electrical or mechanical defects after 100 cycles
of engagement and disengagement.
Contact
Millivolt Drop:
No. 16 contacts - 100 millivolt drop* using
16 AWG wire. Test current 13 amps.
*Less drop through wire. |